WGLL Rank Tubes Cooler

WGLL Rank tubes  cooler has horizontal and vertical type is applied in metallurgy , mine ,light  industry ,food industry etc. to cool the lubricant and hydraulic oil in the  lubrication system and hydraulic system. The heat transfer adopts ; for the  WGLCQ type is wing tube ,and water side passage with two tube range stuffing  box and floating tubes ; for the WGLLQ type is bare tube ,water-side passage  adopts tow tube range or four tube range stuffing box and floating tubes ; and  WGLLQ5、WGLLQ6、WGLLQ7 series are vertical type. The media viscidity is 10~460mm2/s,working temperature lesser than 100℃. 


type DN mm nominal cooling area m2
WGLCQ1 0.63(D)
1(F)
1.6(W)
0.4 0.6 0.8 1 1.2 - - -
WGLCQ2 1.3 1.7 2.1 2.6 3 3.6 - -
WGLCQ3 4 5 6 7 8 9 10 11
WGLCQ4 13 15 17 19 21 23 25 27
WGLCQ5 30 34 37 41 44 47 50 54
WGLCQ6 55 60 65 70 75 80 85 90
WGLLQ1 0.63(D)
1(F)
4 5 6 7 - - - -
WGLLQ2 12 16 20 24 28 - - -
WGLLQ3 35 40 45 50 60 - - -
WGLLQ4 80 100 120 - - - - -
WGLLQ5 160 200 - - - - - -

Example of order:A rank tubes cooler its nominal cooling area is 1.3㎡,nominal pressure 
                              1.0MPa,the type of heat transfer is wing tube
                              WGLCQ1-1.3/1.0 cooler JB/T 7356-1994
                              A vertical rank tubes cooler its nominal cooling area is 60㎡,nominal pressure 0.63MPa,
                              the type of heat transfer is bare tube , water side passage if four tube range;
                              WGLCQ5-6.0/0.63 cooler JB/T 7356-1994

Prev:No
Next:WXHZ Electric Controller of Oil Lubrication Device